The main parameters
Original burner
Huijin Burner
Coal consumption at kiln head(t/h)
8.1
7.8
Coal consumption at kiln tail(t/h)
12.15
12.1
Kiln feeding(t/h)
210
210
Secondary air temperature(℃)
1080
1070
Tertiary air temperature(℃)
930
935
C1 outlet temperature(℃)
347
333
Kiln tail temperature(℃)
1120
1080
Primary air amount(m³/min)
80
58.8
Primary air pressure(kPa)
36
46
Primary air blower current (A)
141
151
Kiln head blower air amount(m³/min)
37.5
37.5
Kiln head blower air pressure(kPa)
13.5
26.5
Kiln head blower current(A)
41
51
Dosage of ammonia(t/d)
5.46
5.61
Clinker KH value
0.89
0.89
Clinker 3-day strength(MPa)
29.6
29.6
Clincker standard coal consumption(kg/t)
116.5
115
Copyright 2020 Huijin intelligent equipment all rights reserved