The main parameters
Original burner
Huijin Burner
Coal consumption at kiln head(t/h)
14.0
13.5
Coal consumption at kiln tail(t/h)
17.0
16.5
Kiln Feeding(t/h)
410
415
Secondary air temperature(℃)
1130
1150
Tertiary air temperature(℃)
915
930
C1 outlet temperature(℃)
345
335
Kiln tail temperature(℃)
1180
1150
Primary air amount(m³/min)
145.8
76.0
Primary air pressure(kPa)
28.0
50
Primary air blower current(A)
230
223
Kiln head blower air amount(m³/min)
85.6
45
Kiln head blower air pressure(kPa)
28.0
31.0
Kiln head blower current (A)
215
145
Dosage of ammonia(t/h)
0.667
0.444
Clinker KH value
0.92
0.93
Clinker 3-day strength(MPa)
29
30
Clinker 28-day strength(MPa)
50
52
Standard coal consumption(kg/t)
92
90
Copyright 2020 Huijin intelligent equipment all rights reserved